Gurgling radiators or cold spots? Air may be trapped in your heating system. Usually, you can resolve it easily. Learn how air enters, when to bleed the system and how to do it for boilers, hybrid and all-electric heat pumps.
Gurgling radiators or cold spots? Air may be trapped in your heating system. Usually, you can resolve it easily. Learn how air enters, when to bleed the system and how to do it for boilers, hybrid and all-electric heat pumps.
Air can enter during refilling, temperature changes or through small leaks. It collects at high points and prevents proper hot water circulation, leaving radiators insufficiently warm and causing gurgling.
Trapped air reduces efficiency: heat distributes poorly, energy use rises and unnecessary wear can occur. Bleeding restores free water circulation, an important maintenance task.
A heat pump relies on water circulation. Trapped air prevents proper operation and risks noise, faults or damage. A well-bled system improves comfort, efficiency and lifespan.
Bleeding is straightforward, though steps vary by system. Start downstairs and work upwards: air rises, so the highest radiators trap the most. Usually, you begin in the living room.
What do you need?
Important: whether you have a heat pump or boiler, water pressure must be correct, between 1.5 and 2 bar. Check before starting. After topping up the water, you MUST bleed the heating system.
A hybrid heat pump works with your boiler, so bleeding follows largely the same process.
Have a Weheat system with smart zone control? Open all zones for proper circulation. You can also start the air-purge programme through the app or portal.
For a fully electric system without a boiler, the steps differ slightly but are just as simple:
A few simple steps help bleed your Weheat system properly for optimum operation. First, ensure correct pressure near the heat source, between 1.5 and 2 bar depending on installation. Check and adjust if necessary.
Open any automatic air vents so air can start escaping. Then start the air-purge programme through the portal or app to remove trapped air faster.
If you have zone control, ensure it is activated with all relevant rooms open so water circulates properly. Then begin manual bleeding.
Visit all bleed points, including radiators, underfloor heating manifold and buffer tank and cylinder connections. Open manual vents individually until no more air escapes, then close them.
Repeat if needed. Once no air escapes anywhere, stop the programme and close automatic air vents.
Finally, start a heating programme to check that everything works correctly, confirming optimum system performance.
Annual bleeding takes little effort and makes a big difference. How often is enough? For most households, bleed the system once a year ideally at the start of heating season, in September or October, when air is most likely after months of lighter use.